Installation is not in the price included!** Installatie is niet in de prijs inbegrepen!**
...Someone to rely on OCEAN Overseas s.r.l. – ITALY |
|||
Parameter |
Unit |
Value |
|
Model |
-- |
ACSI 9 0C A+ |
|
Power Supply |
Rated Voltage |
V~ |
220-240 |
Rated Frequency |
Hz |
50 |
|
Phases |
-- |
1 |
|
Power Supply Mode |
-- |
Indoor |
|
Cross-sectional Area of Power Cable Conductor |
mm2 |
1.00 |
|
Recommended Power Cable(Core) |
N |
3 |
|
Min/Max. Voltage |
V |
185/264 |
|
Cooling Capacity |
W |
2650 |
|
Cooling Capacity |
Btu/h |
9000 |
|
Min. Cooling Capacity |
W |
450 |
|
Min. Cooling Capacity |
Btu/h |
1500 |
|
Max. Cooling Capacity |
W |
3230 |
|
Max. Cooling Capacity |
Btu/h |
11000 |
|
Cooling Power Input |
W |
825 |
|
Min. Cooling Power Input |
W |
200 |
|
Max. Cooling Power Input |
W |
1420 |
|
Cooling Current |
A |
3.7 |
|
Rated Input |
W |
1420 |
|
Rated Current |
A |
6.3 |
|
EER |
W/W |
3.21 |
|
EER |
(Btu/h)/w |
10.96 |
|
SEER |
-- |
15.00 |
|
Energy Class |
-- |
5 |
|
Air Flow Volume |
m3/h |
560/490/430/330 |
|
Air Flow Volume |
CFM |
330/288/253/194 |
|
Dehumidifying Volume |
L/h |
0.80 |
|
Dehumidifying Volume |
PINT/D |
1.69 |
|
Application Area |
m2 |
12-18 |
|
|
Fan Type |
-- |
Cross-flow |
Fan Diameter Length(D×L) |
mm |
Ф98×580 |
|
Fan Diameter Length(D×L) |
inch |
3 6/7×22 5/6 |
|
Cooling Speed |
r/min |
1300/1200/1050/800 |
|
Heating Speed |
r/min |
/ |
|
Fan Motor Power Output |
W |
20 |
|
Fan Motor RLA |
A |
0.215 |
|
Fan Motor Capacitor |
μF |
1 |
|
Heater Power Input |
W |
/ |
|
Evaporator Form |
-- |
Aluminum Fin-copper Tube |
|
Evaporator Pipe Diameter |
mm |
φ7 |
|
Evaporator Pipe Diameter |
inch |
2/7 |
|
Evaporator Row-fin Gap |
mm |
2-1.5 |